Try it yourself · Class 12 Physics · Alternating Current
Transformer: change the turns and the load
A transformer has a primary of 100 turns on a 230 V rms supply. You choose the number of turns on the secondary and the load resistance. The same flux goes through every turn, so the secondary voltage follows the turns ratio. In this simulation 5 percent of the input power is lost, so the efficiency is fixed at 95 percent.
, , . V, , a fixed 5% loss.
The simulation needs JavaScript; everything it shows is explained below.
What to change
- Slide the secondary turns from 10 to 400.
- Slide the load from 2 to 200 ohm.
- Read the voltage, currents, powers and efficiency in the readout.
What to watch
- With and the secondary voltage is 115 V, the current 5.00 A and the output power 575 W. The input power is 605.3 W.
- With the transformer steps up: 460 V, and the secondary current is 20 A with the same load.
- Raising raises in proportion, but the primary current rises faster, with the square of the ratio when the load is fixed.
- The ratio is 0.526 at , equal to times 1.05, so it is 5 percent above the ideal value because of the loss.
The formula
, and are the voltage, current and number of turns of the primary (p) and secondary (s). The efficiency is output power divided by input power.
Try these questions
Work each one out with the simulation, tap to see the answer, then try the chapter quiz.
-
CBSE 2025
A transformer is connected to a 200 V ac source. The transformer supplies 3000 V to a device. If the number of turns in the primary coil is 450, then the number of turns in its secondary coil is –- 30
- 450
- 4500
- 6750
Show the answer
(D) 6750 -
Bihar Board 2019
In a step-up transformer, no, of turns in primary and secondary coils are and , thenShow the answer
(B)
Take the Alternating Current chapter quizRead it in our Alternating Current notesNCERT Alternating Current chapter
More to try in Alternating Current
AC through R, L and C: change the frequencyAn AC source at 100 V peak is joined to one element.Series LCR resonance: change R and CA series LCR circuit with H is driven by a 100 V source whose frequency you can scan.LR and RC circuits: change the frequencyA resistor of 100 ohm is joined in series with either an inductor of 0.1 H or a capacitor of 10 microfarad, across a 100 V peak source.LC oscillations: change L, C and the resistanceA charged capacitor is joined to an inductor.AC generator: change the turns and the speedA coil turns in a uniform magnetic field of 0.5 T.Power in an AC circuit: change the phase angleA load takes 220 V rms and 5 A rms.Power factor correction: add a capacitorA load of 2 kW at 220 V, 50 Hz has a power factor of 0.8 lagging.