Try it yourself · Class 12 Physics · Alternating Current

Transformer: change the turns and the load

A transformer has a primary of 100 turns on a 230 V rms supply. You choose the number of turns on the secondary and the load resistance. The same flux goes through every turn, so the secondary voltage follows the turns ratio. In this simulation 5 percent of the input power is lost, so the efficiency is fixed at 95 percent.

, , . V, , a fixed 5% loss.

The simulation needs JavaScript; everything it shows is explained below.

What to change

  • Slide the secondary turns from 10 to 400.
  • Slide the load from 2 to 200 ohm.
  • Read the voltage, currents, powers and efficiency in the readout.

What to watch

  • With and the secondary voltage is 115 V, the current 5.00 A and the output power 575 W. The input power is 605.3 W.
  • With the transformer steps up: 460 V, and the secondary current is 20 A with the same load.
  • Raising raises in proportion, but the primary current rises faster, with the square of the ratio when the load is fixed.
  • The ratio is 0.526 at , equal to times 1.05, so it is 5 percent above the ideal value because of the loss.

The formula

, and are the voltage, current and number of turns of the primary (p) and secondary (s). The efficiency is output power divided by input power.

Try these questions

Work each one out with the simulation, tap to see the answer, then try the chapter quiz.

  1. CBSE 2025

    A transformer is connected to a 200 V ac source. The transformer supplies 3000 V to a device. If the number of turns in the primary coil is 450, then the number of turns in its secondary coil is –
    1. 30
    2. 450
    3. 4500
    4. 6750
    Show the answer
    (D) 6750
  2. Bihar Board 2019

    In a step-up transformer, no, of turns in primary and secondary coils are and , then
    Show the answer
    (B)

More to try in Alternating Current

Every simulation in the Lab