Try it yourself · Class 12 Physics · Alternating Current
Power factor correction: add a capacitor
A load of 2 kW at 220 V, 50 Hz has a power factor of 0.8 lagging. It draws 11.36 A. A capacitor placed across it supplies current that cancels part of the lagging current across the voltage. The phasor picture shows the load current , the capacitor current and the current from the supply.
Load: kW, V, lagging. cancels the part of across .
The simulation needs JavaScript; everything it shows is explained below.
What to change
- Slide the capacitor from 0 to 200 microfarad.
- Watch the phasors: pulls the supply current’s tip upward.
- Read the supply current, power factor and the line loss compared with having no capacitor.
What to watch
- With no capacitor the supply current is 11.36 A at power factor 0.800 and the line loss is 100 percent of its reference.
- At 50 microfarad A, the supply current falls to 9.69 A, the power factor rises to 0.938 and the line loss falls to 73 percent.
- The best value is 98.6 microfarad. There the supply current is 9.09 A, the power factor is 1.000 and the line loss is 64 percent.
- Too much capacitor over-corrects: at 200 microfarad the power factor is 0.792 leading and the line loss is back above 100 percent.
The formula
is the capacitor’s current, the rms supply voltage, the angular frequency and the load’s phase angle. The loss in the supply line is .
Try these questions
Work each one out with the simulation, tap to see the answer, then try the chapter quiz.
-
JEE Main 2021
A choke coil is needed to operate an arc lamp at 160 V (rms) and 50 Hz. The arc lamp has an effective resistance of when running at 10A (rms). The inductance of the choke coil is –- H
- H
- H
- H
Show the answer
(A) H -
CBSE 2024
An inductor, a capacitor and a resistor are connected in series with an ac source . Derive an expression for the average power dissipated in the circuit. Also obtain the expression for the resonant frequency of the circuit.Show the answer
;
Take the Alternating Current chapter quizRead it in our Alternating Current notesNCERT Alternating Current chapter
More to try in Alternating Current
AC through R, L and C: change the frequencyAn AC source at 100 V peak is joined to one element.Series LCR resonance: change R and CA series LCR circuit with H is driven by a 100 V source whose frequency you can scan.LR and RC circuits: change the frequencyA resistor of 100 ohm is joined in series with either an inductor of 0.1 H or a capacitor of 10 microfarad, across a 100 V peak source.LC oscillations: change L, C and the resistanceA charged capacitor is joined to an inductor.AC generator: change the turns and the speedA coil turns in a uniform magnetic field of 0.5 T.Power in an AC circuit: change the phase angleA load takes 220 V rms and 5 A rms.Transformer: change the turns and the loadA transformer has a primary of 100 turns on a 230 V rms supply.